All industries

Industrial valves for power generation and steam systems

Power-plant valve selection is governed by the pressure-temperature combination, thermal cycling, feedwater chemistry and unit start-up regime—not pressure alone. Body, bonnet, trim, bolting, packing, end connections and actuation must be reviewed for each line-list position.

Operating context

Superheated steam sets limits for body material, bolting, gasket and packing systems.

Thermal cycles and rapid warm-up can change alignment, operating torque and seat tightness.

Feedwater and condensate duties require review of velocity, differential pressure, cavitation and flashing risk.

Selection factors

  • design pressure and temperature as one rating point
  • material grade, toughness requirements and heat treatment
  • bolted-bonnet or pressure-seal construction, stem and packing
  • manual, geared or electric actuation with torque basis
  • NDT scope, pressure testing and witness or hold points

Typical applications

  • main and auxiliary steam
  • boiler feedwater and condensate
  • cooling and service-water systems
  • district-heating networks
  • balance-of-plant utility systems

Document package

  • guaranteed valve datasheet
  • material certificates and heat-number traceability
  • NDT and dimensional reports
  • shell and seat pressure-test records
  • contract-specific manufacturing record book

For power-service inquiries, TAZ requests the design cases and governing specification before confirming an execution. Suitability for critical steam or a named plant service is stated only after engineering review.

Send a line list or RFQ

Other industries